Door Sweep and Subframe - Accessories

Finishing

Panic devices

AUTOMATIC DOOR SWEEP

On request, Univer and Proget doors are available with an automatic door sweep to prevent air drafts from entering through the crack between the leaf and the floor. It complements the FF sealing applied to the frame to provide better acoustic insulation and better air sealing for the door. It is applied on the push side by using screws to attach it directly to the sheet metal of the door, after which the mechanism is completely covered with an anodized aluminum profile. On request, it can also be provided in the same color as the door leaf. It is applied on site following door installation so that it can be adjusted to the actual leaf height.

Lengths avail. FM L active leaf FM L secondary leaf
430 mm from 500 to 520 from 407 to 506
530 mm from 521 to 620 from 507 to 606
630 mm from 621 to 720 from 607 to 706
730 mm from 721 to 820 from 707 to 806
830 mm from 821 to 920 from 807 to 906
930 mm from 921 to 1020 from 907 to 1006
1030 mm from 1021 to 1120 from 1007 to 1106
1130 mm from 1121 to 1220 from 1107 to 1206
1230 mm from 1221 to 1320 from 1207 to 1306
1330 mm from 1321 to 1340 from 1307 to 1330

PROTECTIVE PLATES AND KICKPLATES

On request for 1 and 2 leaf Univer and Proget doors, specifying the side of application (pull or push). Their main function is to protect the parts of the door that are vulnerable to being scraped by carts, hospital beds, etc. They are made of AISI 304 satinized stainless steel sheet metal with a standard height of 230 mm. For on-site attachment with two-sided adhesive factory applied on the back, at the bottom of the door (kick plate) or at handle height (protective plate).

Protection plates

Kick plates


Holes are factory prepared for the passage of the handle panel and cylinder

Holes are factory prepared for the passage of the handle panel and cylinder.

DRIP-STEEL PROFILE

On request for 1 and 2 leaf Univer and Proget doors, specifying the side of application (pull or push). It is applied to the exterior side of the door on site after being cut to measure, to be attached with the screws provided.

Lengths avail. FM L door leaf
710 mm to 800
810 mm to 900
910 mm to 1000
1260 mm to 1350

WALL SCREWS FOR FASTENING WITHOUT PLUGS

Field of use: installation of Proget REI 60/120 and multipurpose doorframes to the wall or subframe using screws but no plugs. Designed for installation into concrete, full bricks, half-full bricks, lightened cement and other materials. Advantages: saves time and money thanks to direct attachment of the frame to the wall, with no need to enlarge the holes for plugs. Thanks to the black galvanization, the screws blend in smoothly with the FC sealing.

Dimensions description
Ø 7.5 x 50 mm for attachment to metal subframes
Ø 7.5 x 60 mm for attachment to concrete and especially thick walls
Ø 7.5 x 80 mm for attachment to walls of average thickness
Ø 7.5 x 100 mm for attachment to walls of lower thickness

NOTE Holes should be drilled using a Ø 6 mm stone drill bit.


SUBFRAME

Subframe (to be ordered) in hollow 30 x 15 x 2mm steel profiles (recommended for REI 60 and REI 120 Proget doors) equipped with anchors for mortar fixing and spacers that are to be removed during final installation.

Horizontal cross section


Vertical cross section

The MAC system makes it possible to activate the handle to open the door using the same mechanical components as for normal functioning. The particularity of the MAC system is that it concentrates all of the command and control functions in the lock, which simplifies the electrical work required on site.

The MAC system offers multiple advantages, such as:

  • possibility of 12 V AC/DC or 24 V AC/DC power supplies, which avoids problems due to inadequate voltage
  • low current absorption:
    • at 12 V the startup current is 500 mA for the first 5-6 sec., before changing to a 250 mA maintenance current
    • at 24 V the startup current is 1 A for 300 millisecond., before settling to 500 mA for 4-5 sec. and finally changing to a 250 mA maintenance current for the remaining 25 sec.
  • timer incorporated, time set at 30 sec. with automatic reset (zeroing of the timer) every time the door is opened, eliminating the need for external timers
  • red/green LED on the backplate to prevent useless forcing of the handle by signaling whether the opening system is active or not
  • continuous handle activation (always open when desired)
  • remote LED for remote signaling of lock activation/deactivation

The MAC system comes pre-assembled with the door, including the wiring inside the door leaf and the electrical contacts between the leaf and the frame.

Included pre-assembled on the door: anti-panic lock with solenoid and electronic chip with timer incorporated (1), double electrical contacts between leaf and frame (2), internal wiring inside the leaf (3) Included in the package: handle and backplate with red/green LED and connectors (4) Not included: power supply for doorframe contacts (5), opening button and command accessories (6)


Diagram of components

Nylon and stainless steel handles with red/green LED

MAC 1 SYSTEM

Operation mode The MAC 1 system controls access from the pull side of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates the handle, while opening is always possible from the push side by means of the panic bar or emergency handle. Activation of the handle is signaled by illumination of the “green LED,” while the “red LED” indicates when the handle is idle. Both LEDs are off when no power is being supplied.


MAC 2 SYSTEM

Operation mode The MAC 2 system controls access from both sides of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates both handles. Activation of both handles is signaled by illumination of the “green LED,” with the “red LED” signaling when the handles are idle. Both LEDs are off when no power is being supplied.

Time mode In this mode, the activation time lasts 30 seconds before the handle is returned to idle. If the door is opened within the 30 seconds, the timer is automatically reset to zero.

Time mode In this mode, the activation time lasts 30 seconds before both handles are returned to idle. If the door is opened within the 30 seconds, the timer is automatically reset to zero.

Continuous mode “open setting”: in this mode, handle activation is controlled by an electrical switch (not included) that provides continuous power to the MAC 1 lock. The green LED remains lighted, being turned off only from the time the door is opened until it is fully closed once again.

Continuous mode “open setting”: in this mode, the activation of both handles is controlled by an electrical switch (not included) that provides continuous power to the MAC 2 lock. The green LED remains lighted for both handles, being turned off only from the time the door is opened until it is fully closed once again.

MAC 1 can be combined with any BM type panic bar and M3 emergency handles.

MAC 2 can be combined with M1 (black nylon) and M1X (stainless steel) handles.

NOTE Both systems have been REI 120 fire-tested to ensure compliance of the certified product

ELM/MT MULTI-VOLTAGE ELECTRIC HANDLE

The MAC 1 system controls access from the pull side of the door. With the lock locked by key, opening is only possible with electrical consent (button, switch, badge reader, etc.) which activates the handle, while opening is always possible from the push side by means of the panic bar or emergency handle. Activation of the handle is signaled by illumination of the “green LED,” while the “red LED” indicates when the handle is idle. Both LEDs are off when no power is being supplied. The illumination of a green LED and sounding of an acoustic signal (buzzer) indicate handle activation, while a red LED indicates deactivation.

When ordered together with the door, the ELM/mt system includes: electric handle, electrical contacts between the leaf and the frame, power cable inside the door connected to electrical contacts, command panel, lock and fixing screws.

If ordered separately from the door, the system includes: electric handle, command panel and fixing screws.

Technical data
power supply 12 Vcc/Vca – 24 Vcc/Vca
current absorbed at 12 V 500 mA
current absorbed at 24 V 200 mA
startup current at 12 V 700 mA
startup current at 24 V 300 mA

ELM/CISA MULTI-VOLTAGE CISA ELECTRIC HANDLE

Controlled door opening system that employs an electronic device to activate the handle. Equipped with a separate timer (for insertion into the switch box) which can be set for different opening times: from a minimum of 0,1 second to a maximum of 10 days. Equipped with green LED that signal activation of the handle.

The ELM/cisa system includes: electric handles, 2 meters of power cable, cable sleeve for the connection between the leaf and the frame, 8/9 square spindle, fixing screws, adjustable timer packaged separately.

Technical data
power supply 12 Vcc/Vca – 24 Vcc/Vca
current absorbed 330 mA
startup current 800 mA
operational temperature -20°C ÷ +80°C
max. relative ambient humidity 95%

NOTE The electric handle requires assembly.


OPENING SYSTEM FOR COMBINATION WITH ELM/MT OR ELM/CISA ELECTRIC HANDLE

Panic bars The controlled opening direction is from the pull side of the door (electric handle side). Locking the lock by key blocks the electric handle functioning, while opening is still possible via the panic bar on the push side. Use: one- or two-leaved doors for anti-panic exits when access control is desired on the pull side.


Exus

Twist


Slash

MSC Handles Use: one- or two-leaved doors when control is desired for one of the two opening directions. Locking with the key blocks opening in both directions. Controlled opening may be for either the push or pull direction, depending on where the electric handle is applied.

MCC/S Handles Use: for one- or two-leaved doors where access is to be controlled from the pull side only (electric handle side). Locking with the key blocks opening from the push side, but not from the side where the electric handle is applied.


MSC                                                            MCC/S

OPENING SYSTEM FOR COMBINATION WITH ELM/MT ELECTRIC HANDLE

Emergency handles M3 Use: one- or two-leaved doors for emergency exits when access control is desired on the pull side. The controlled opening direction is from the pull side of the door (electric handle side). Locking the lock by key blocks the operation of the electric handle, while opening remains possible via the M3 emergency handle.


M3                                                            HOT-CIL

Emergency handles HOT/CIL Use: for the doors of hotel rooms The controlled opening direction is from the push side of the door (electric handle side). Closing with the thumbturn latch from inside the room, the opening by electric handle is possible only with an electric consent. Opening is always possible from the room side of the door.

ELECTROMAGNETS 13700 TD

This system is for use in special situations when the doors remain closed and should only be opened with electrical consent. The electrically powered electromagnet holds the door closed with a holding force of approximately 300 kg, rendering the action of the handle ineffective. Only electrical commands (badge reader, key button, etc.) or electrical consent from the fire detector system can deactivate the electromagnet making a door opening possible.

Operation mode The door is held closed by the electromagnet (01) and the bolt of the lock. Opening from the outside can happen via magnetic card (04) using the Badge reader (02) of the card control system or any other system of choice and by retracting the bolt using the handle or key. From the inside, the deactivation of the electromagnet is caused by the unlock button (03) (also remotely) or with the same system used for the pull side, while the locking bolt must still be retracted using the handle or key. The activated electromagnet signals its state with a red LED, whereas the green LED signals the temporary deactivation. Further a relay AC/DC signaling the electromagnetic state is supplied.


NOTE Unlocking of the door is only possible if the door is not locked by key.

Technical data
model 13700 TD withstand force fino a 300 Kg.
power supply 12/24 Vcc time delay 0 ÷ 90 sec.
current absorbed at 12 V 500 mA electrom. compatib standard EMC – UNI CEI 70011
current absorbed at 24 V 250 mA certificate Nr. 0123/02

COMPONENTS INCLUDED WITH THE ELECTROMAGNET CONTROLLED OPENING SYSTEM

For Proget doors Electromagnet 13700 TD holding force 300 kg, 12/24 V DC, fastener plate, anchor with stainless steel fastener backplate.

For Rever/Univer doors Electromagnet 13700 TD withstanding force 300 kg, 12/24 V DC, fastener plate and angle bar, anchor with stainless steel fastener backplate.

Control system:

  • “Access” code keypad
  • Card-based control system
  • Biometric “TOCA access” reader
  • Unlock button

NOTE Detailed specifications for the Control system are found on the “Command accessories” page.


PROGET Electromagnet                      REVER/ UNIVER Electromagnet